For
over 45 years Industrial Acoustics Company has been a leader in
the development and application of noise control technology. Since
1949 IAC has designed and installed thousands of noise control
systems at power generating and distribution facilities worldwide.
IAC offers
laboratory and field proven noise control products to satisfy
guarantees and minimize owner risk. Noise control for low frequencies
can be a critical issue in obtaining regulatory and community
acceptance.
This guide
illustrates common noise sources typical to power generation
facilities and indicates the noise attenuating devices that
may be used to control them.
GAS
TURBINES-Low and High Frequency Noise Controlled with Power-Flow®
Silencers
Complete
IAC noise control systems including Power-Flow® Intake and
Exhaust Silencers and Noishield Enclosures are available to
reduce gas turbine noise. Power-Flow Silencers may include dissipative
and/or reactive elements to provide the most cost-effective
means of satisfying applicable noise criteria. IAC has designed
and manufactured Power-Flow Silencers for most power generation
gas turbines. Designs are available for many replacement silencers
applications. IAC's proven expertise in the application of resonator
technology will provide economical solutions to any special
low-frequency noise problems.
STEAM
TURBINES-Noise contained with Noishield® Cladding and Enclosures
Steam turbine cladding is accomplished with Moduline® Noishield
Component System designed to provide high Sound Transmission
Loss (STC) and Sound Absorption (NRC) performance.The modular
system is engineered for fast track installation by semi skilled
personnel. IAC's cladding system can be designed to allow visual
inspection and maintenance of equipment with minimal disruption
of service for indoor and outdoor facilities.
GENERATORS-Operate
quietly within Noishield® Enclosures
Noishield
enclosures, room offices and partitions can be designed to provide
noise reduction performance in accordance with acoustical and
space requirements. IAC designs acoustic structure in its Aero-Acoustic
Laboratory to meet specific noise reduction, aerodynamic, thermodynamic,
structural and mechanical requirements. If discrete low or high
frequency peak noise sources are a factor, IAC can provide proven
designs to attenuate them.
VENTILATION - Noise controlled with Noishield® Louvers
IAC's Louvers provide effective weather barriers together with
noise control and low pressure drop for air intakes, supply
systems, equipment rooms, penthouses, noise barriers, cross
talk silencers, cooling towers, and others. Noishield Louvers
offer decorative exteriors, color coordinated finished and corners
for architectural compatibility. Supplied in galvanized steel
or mill finish aluminum for field painting; options include
stainless steel and laminated finishes.
Quiet -
Duct Silencers, including low frequency designs, are available
in more than 26 standard models in many cross - sections and
lengths for a wide range of acoustic and aerodynamic criteria.
INDUCED
DRAFT FANS - Control noise with ACoustic FIlter (ACFI) Silencers
ACFI
Silencers are designed to attenuate blade pass and harmonic
frequencies even after buildup of fly ash or other deposits.
ACFI Silencers are engineered to provide broad band Dynamic
Insertion Loss (DIL) and minimum pressure drop. Parallel air
paths help minimize pressure drop and permit inspection and
maintenance of sound absorbing cavities without splitter removal.
FORCED
DRAFT FAN-Control Noise with Power-Flow® Silencers &
Noishield Housings
Power Flow Silencers for forced draft and induced draft
fans are designed to economically satisfy a wide range of acoustical
and aerodynamic requirements: they are laboratory rated to assure
specified results.
Noishield Fan Housings, constructed of IAC Moduline acoustically
rated and field tested components, are manufactured with corrosion
resistant material for long life essential to power plant operations.
TRANSFORMERS-Hum
contained inside Moduline Noishield® Enclosures or Barrier
Walls
Transformers are often one of the most difficult noise problems
to control. Due to the general predominance of transformer "hum"
and cooling fan noise at 100 or 120 Hz, transformers require
noise barriers highly rated for transmission loss and sound
absorption at these frequencies. Moduline Enclosures and Noishield
Barriers are rated from STC 40 to STC 70 (special designs available)
and at NRC 0.95 to absorb incident sound.
Enclosures and Barriers can be built to meet dimensional and
noise reduction requirements. Constructed of galvanized or stainless
steel, the systems can be readily remounted for transformer
maintenance. Noishield barriers break the noise source line
of sight and improve plant appearance.